4065 Stanley Ave
Niagara Falls, ON L2E 4Z1
905-354-4424

Local Reviews
for niagara falls, on

Rated 4.9 out of 5 stars based on 1315 customer reviews

Excellent service as usual

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service very friendly

Joe and everyone else who helped install our fireplace were very informative, professional and friendly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Good workers very professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Great, friendly service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent

Joe did great work thanks Joe

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fantastic Service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Install crew was great, quick, efficient and friendly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service

great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

A big thank you to Wesley for making our fireplace look brand new!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

Shariq was friendly, personable and professional.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

Very pleased with service. The technician who came to my home, Shalik, was pleasant and took the time to take photos and explain the work being done. Would highly recommend.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fireplace service awseome personality

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Got my vote!!

Great scheduling service. Great arrival time service. Great completion service. Friendly and professional.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Great service from start to finish! Wesley was prompt, polite and professional. Highly recommend.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for niagara falls, on

Trevor S.

Trevor S. Job Checkin

Furnace and Humidifier Installation


Joe P.

Joe P. Job Checkin

Tankless Water Heater Installation


Gary T.

Gary T. Job Checkin

Furnace Service Call


Wesley P.

Wesley P. Job Checkin

Fireplace maintnenace. Fireplace operating normally after cleaning. Sometimes it does light but after a couple retries it will stay light. This model is difficult to reach pilot assembly without removal of side panels, and the side panels are stuck and will not budge without damage. Advised client if issue of not staying light continues we should replace pilot assembly as removal of the panels and everything , it would be more worth to replace parts than try to clean as cleaning pilot assembly may not fix the issue.


Wesley P.

Wesley P. Job Checkin

Service Type: Boiler & Thermostat Check Equipment: Navien NCB-H Combi Boiler, Fan Coil Air Handler, Basic Thermostat, Outdoor Temperature Sensor Client Concern Client noted indoor temperature reaching 20–20.5 °C when setpoint was 19.5 °C. Inspection & Findings Checked all system settings and parameters; boiler and air handler operating normally. Slight overshoot may be due to outdoor reset curve or coil heat lag. Thermostat batteries were low; replacing batteries could help improve accuracy. Recommendations Monitor system after battery replacement. If temperature consistently rises >1.5 °C above setpoint while boiler/fan continue running, thermostat contact may be stuck and thermostat replacement recommended. Status: System operating normally; no other issues observed.


Joe P.

Joe P. Job Checkin

Gas fireplace installation


Joe P.

Joe P. Job Checkin

Evans Select 60


Andrew S.

Andrew S. Job Checkin

Fireplace was not maintaining set temp on thermostat. Customer had been noticing burners dropping out at times during a call for heat. Performed full cleaning of fireplace, cleaned glass. Found small stress fractures in corners of glass. Not quite a crack but definitely something to keep an eye on. After performing maintenance on fireplace it is working well , running consistently and burners are not dropping out. Advised customers to keep an eye on the operation of the fireplace and call us if the problem reoccurs. Office will put together a quote for red tag


Joe P.

Joe P. Job Checkin

Installed furnace


Wesley P.

Wesley P. Job Checkin

Furnace maintenance and inspection. No concerns noted. Furnace running within spec. Humidifier pad still in good condition. Humidifier operating normally.


Trevor S.

Trevor S. Job Checkin

Furnace Replacement


Shalik M.

Shalik M. Job Checkin

Initial Findings: ​System Status: Thermostat was calling for heat, but the furnace was unresponsive. ​Safety Note: Labeled the furnace service switch for easier identification. ​Error Codes: EE0 (Lockout), EE2 (Pressure Switch Open), and EE5 (Open Fuse). ​Actions Taken: ​Drainage & Seals: Drained accumulated condensation from the inducer motor. Inspected all tubing and secured the pressure switch hosing with a zip tie to ensure a tight seal. ​Pressure Adjustment: Calibrated the low-fire gas pressure from 2.2" wc to the optimal 1.9" wc. ​Testing: Following drainage and pressure adjustments, the furnace was tested and is operating normally (running continuously for 25+ minutes). Required Part: To prevent future moisture buildup, a Westlake drain diverter tee is required. ​Follow-up: We have ordered the part and will schedule the installation with the tenants as soon as it arrives.


Joe P.

Joe P. Job Checkin

Installed furnace and air conditioner


Shalik M.

Shalik M. Job Checkin

Error Code 228: Unable to perform successful pressure switch calibration. Measured suction on pressure switch from collector box - .14 / -1.10"wc. Pressure switch being ordered for swap out.


Shalik M.

Shalik M. Job Checkin

Furnace Maintenance: Replaced the filter and inspected the Ultraviolet lights. Flushed the condensate P-trap and drain lines to maintain clear, efficient flow. Checked pressure switch tubing to ensure reliable performance. Cleaned and polished the flame sensor for optimal ignition. Ran full diagnostics to confirm the system is running smoothly and efficiently